Xylem - WTW TetraCon 925 301710
PART NO: X-301710
Price: €602.00
Qty In Stock: 2
Robust, general purpose 4-electrode conductivity cell with graphite electrodes incorporating integral temperature sensor
Memory for 10 calibrations, stored serial number, measuring range 10 µS/cm to 2000 mS/cm ±0.5% of value, 0.0 to 100.0°C
±0.2°C with 1.5m cable.
Memory for 10 calibrations, stored serial number, measuring range 10 µS/cm to 2000 mS/cm ±0.5% of value, 0.0 to 100.0°C
±0.2°C with 1.5m cable.
Conductivity cell probes Standard conductivity cell probe TetraCon® 325: 4-pole cell with integral temperature sensor. Cable length 1.5 metres. Measuring range: 1µS/cm to 2µS/cm. Special conductivity cell probe TetraCon® 325/C: As TetraCon® 325, 4-pole cell with integral temperature sensor, but with sensor head made of chemically resistant PEEK. Cable length 1.5 metres. Measuring range: 1µS/cm to 2µS/cm Ultra-pure water conductivity cell probe LR 325/01: With integral temperature sensor and flowthrough vessel D 01/T for measuring very low conductivity ranges (<1 µS/cm) e.g. boiler feed water or deionised water. Cable length 1.5 metres. Min. / max. insertion depth 35 / 110mm and flowthrough, measuring range: 0.001µS/cm to 200µS/cm. Conductivity flowthrough cell TetraCon® DU/T: 4-pole conductivity cell with integral temperature sensor for standard applications. Connection via 10mm diameter tubing nozzles (the adapter cable KKDU with 1 metre cable is required for connection). Filling volume 7ml. Measuring range: 1µS/cm to 1000µS/cm. IDS conductivity cell probe TetraCon® 925: Intelligent digital 4-pole cell with integral temperature sensor. Automatical transfer of the cell constant. For connection to WTW IDS measuring instruments. Cable length 1.5 metres. Measuring range: 1µS/cm to 2µS/cm. IDS conductivity cell probe TetraCon® 925/LV: Intelligent digital 4-pole cell with integral temperature sensor. Fork design, suitable for small volumes (at least 2.5ml) as well as for viscous samples. Automatical transfer of the cell constant. For connection to WTW IDS measuring instruments. Cable length 1.5 metres. Measuring range: 1µS/cm to 2µS/cm. IDS conductivity cell probe LR 925/01: Intelligent digital 4-pole cell with integral temperature sensor and flowthrough cell D 01/T for measuring of low conductivity values (<1µS/cm) e.g. in boiler feed water or ion exchange water. Automatical transfer of the cell constant. Cable length 1.5 metres. Min./max. immersion depth 35/110mm and flow through measurement. Measuring range: 0.01µS/cm to 200µS/cm. Product Specification: Product Type: TetraCon® 925 Electrode: Graphite Shaft: Epoxy resin Length: 120 mm Cell constant: K =0.475 | |
Catalogue Number | 7.653 077 |
Manufacturer | Xylem - WTW |
Manufacturer P/n | 301710 |