Aqualytic CSB Measuring Station AL200 COD VARIO 42892602
PART NO: 4AJ-9920205
Out of Stock (Ships in approx. 3 weeks)
According to ISO 15705. This measuring station from AQUALYTIC® allows the accurate, rapid, and economical determination of waste water COD levels (Chemical Oxygen Demand). Includes a COD photometer, 25 tube tests covering lower measuring ranges, a reactor block for sample digestion and a tube stand.
Photometer specifications
Range: 0 bis 15.000 mg/L
Measurement cycle: ca. 3 seconds
Display: LCD readout
Optics: High-quality Interference Filters
Power: 4 batteries (AA) capacity approx. 53 hours or 15000 tests (continuous operation with backlit switched off)
Overall WxDxH: 190 x 110 x 55 mm
Storage: 16 data sets
Interface: internal interface for test data transfer
Thermoreactor AL125
The required temperatures and reaction time can be selected by using the membrane keypad. The unit works at three different temperatures (100/120/150°C) and four pre-set reaction times (30/60/120/8 minutes). When digestion is complete, the reactor automatically switches off and gives a corresponding LED indication with short beep alarm. The AL125 reactor is fitted with 24 holes for 16 mm diameter vials.
Specifications
Power supply: 230V/50-60 Hz
Power: 550 W
Dimensions 248 x 219 x 171 mm
Weight: 3.9 kg
COD measuring station AL200 COD VARIO
Instrument supplied in carrying case, 4 batteries (AA), adapter for round vials diam. 16 mm, 2 sets of tube tests 0-150 mg/l, 0-1500 mg/l, thermoreactor AL125, tube stand, 2 syringes 1 ml, 2 ml, warranty information, certificate (COC).
Photometer specifications
Range: 0 bis 15.000 mg/L
Measurement cycle: ca. 3 seconds
Display: LCD readout
Optics: High-quality Interference Filters
Power: 4 batteries (AA) capacity approx. 53 hours or 15000 tests (continuous operation with backlit switched off)
Overall WxDxH: 190 x 110 x 55 mm
Storage: 16 data sets
Interface: internal interface for test data transfer
Thermoreactor AL125
The required temperatures and reaction time can be selected by using the membrane keypad. The unit works at three different temperatures (100/120/150°C) and four pre-set reaction times (30/60/120/8 minutes). When digestion is complete, the reactor automatically switches off and gives a corresponding LED indication with short beep alarm. The AL125 reactor is fitted with 24 holes for 16 mm diameter vials.
Specifications
Power supply: 230V/50-60 Hz
Power: 550 W
Dimensions 248 x 219 x 171 mm
Weight: 3.9 kg
COD measuring station AL200 COD VARIO
Instrument supplied in carrying case, 4 batteries (AA), adapter for round vials diam. 16 mm, 2 sets of tube tests 0-150 mg/l, 0-1500 mg/l, thermoreactor AL125, tube stand, 2 syringes 1 ml, 2 ml, warranty information, certificate (COC).
COD measuring station, AL200 COD Vario According to ISO 15705. This measuring station from AQUALYTIC® allows the accurate, rapid, and economical determination of meaningful waste water COD levels (Chemical Oxygen Demand). Easy operation, even by unskilled operators. Comprises of COD photometer, 25 tube tests covering lower measuring ranges, a reactor block for sample digestion and a tube stand. Waterproof acc. to IP 68, 1 hour at 0.1 meter. Specifications: Range: 0 to 15.000 mg/L Measurement cycle: approx. 3 seconds (method dependent) Display: LCD readout Optics: High-quality Interference Filters Power: 4 batteries (AA) capacity approx. 53 hours or 15000 tests (continuous operation with backlit switched off) Overall W x D x H: 190 x 110 x 55mm Storage: 16 data sets Interface: internal interface for test data transfer Product Specification: Product Type: COD measuring station AL200 COD Vario | |
Catalogue Number | 9.920 205 |
Manufacturer | Aqualytic |
Manufacturer P/n | 2892602 |
Type | MD 200 |
PK | 1 |