Xylem - WTW 00798 Phosphate PO4 252045
PART NO: X-252045
Out of Stock (Ships in approx. 3 weeks)
Photometric test kit for measurement of Phosphate PO4
Available ranges:
1.0 - 100.0 mg/l PO4-P
3.0 - 307.0 mg/l PO4
Number of tests: 100 (Reagent tests)
Sample volume required: 8ml
Cuvette type: 10mm
Compatible with photometers:
photoLab S12
photoLab Spectral
spectroFlex
pHotoFlex 1.0 - 50.0 mg/l PO4-P; 3.0 - 153.0 mg/l PO4
Additional information:
For use with seawater.
Reaction:
Models P4/25, P5/25, 00616, 00798, 14543, 14729, 14848, PO4-1 TP, PO4-2,3 TC: phosphorus-molybdenum blue (PMB) analog to ISO 6878 and US Standard Method 4500 P/B,5
Models 14546, 14842: vanadate-molybdate (VM)
Applications:
Wastewater, drinking water, surface water, fertilizers; *sea water: not suitable for PTotal.
Note:
The VM method is falsified by humic matter. Model 14848, 00616, 00798 and 14842: for the determination of total phosphorus crack set 10 and empty round cuvettes or Crack-Set 10-C are required (100 °C or 120 °C, 1 h)
for P6/25 CombiCheck 10 can be used, for P7/20 CombiCheck 20 or CombiCheck 80
Available ranges:
1.0 - 100.0 mg/l PO4-P
3.0 - 307.0 mg/l PO4
Number of tests: 100 (Reagent tests)
Sample volume required: 8ml
Cuvette type: 10mm
Compatible with photometers:
photoLab S12
photoLab Spectral
spectroFlex
pHotoFlex 1.0 - 50.0 mg/l PO4-P; 3.0 - 153.0 mg/l PO4
Additional information:
For use with seawater.
Reaction:
Models P4/25, P5/25, 00616, 00798, 14543, 14729, 14848, PO4-1 TP, PO4-2,3 TC: phosphorus-molybdenum blue (PMB) analog to ISO 6878 and US Standard Method 4500 P/B,5
Models 14546, 14842: vanadate-molybdate (VM)
Applications:
Wastewater, drinking water, surface water, fertilizers; *sea water: not suitable for PTotal.
Note:
The VM method is falsified by humic matter. Model 14848, 00616, 00798 and 14842: for the determination of total phosphorus crack set 10 and empty round cuvettes or Crack-Set 10-C are required (100 °C or 120 °C, 1 h)
for P6/25 CombiCheck 10 can be used, for P7/20 CombiCheck 20 or CombiCheck 80
Photometer photoLab® and photoFlex®, stored test protocols A: Stored in photoLab® S6, S12, photoLab® 6000 Serie and photoLab® Spektral B: Stored in photoLab® S12, photoLab® 6000 Serie and photoLab® Spektral C: Stored in photoFlex® and photoFlex® Turb® Reagent-free tests: Cu - copper plating bath, 690nm, 820nm - copper plating bath - B CrO3 - chromium plating bath - chromium plating bath - B Ni - nickel plating bath - nickel plating bath - B HZ - Hazen colour - Hazen colour - B IFZ - iodine number, 340nm, 455nm - iodine number - B m-1 (DFZ) - colouring - FB445 - B, C m-1 (DFZ) - colouring - FB525 - A, C m-1 (DFZ) - colouring - FB620 - B, C FAU - turbidity 620 - T620 - B E - extinction - extinction - A, B, C SAK - Spectral absorption coefficient at 254 and 436nm photoLab® 6100 VIS (436nm) and UV-VIS photoLab® 6600 (254/436nm) Further tests on demand, range information is based on max. area and can also be smaller for photoFlex®. Product Specification: Product Type: 00798 Description: PO4-P, Phosphate For: B, C Unit: 1.0 - 100.0 mg/l No. of determinations: 100 | |
Catalogue Number | 9.920 955 |
Manufacturer | Xylem - WTW |
Manufacturer P/n | 252045 |
For | B, C |
No. of determinations | 100 |
Type | 00798 |
PK | 1 |
Description | Phosphate, PO4-P |
Unit | 1.0 - 100.0 mg/l |