Your basket is empty

Xylem - WTW KKDU 325 301963
Enlarge

Xylem - WTW KKDU 325 301963

PART NO: X-301963
Price: €179.00
Out of Stock (Ships in approx. 2 weeks)

KKDU 325

Connection cable
- 3.3 ft (1m)
- 8-pin-plug

For flow-through conductivity cells
- TetraCon® DU/T
- TetraCon® DU/TH
- KDU 1/T
- KDU 1/TH

Conductivity cell probes
Standard conductivity cell probe TetraCon® 325:
4-pole cell with integral temperature sensor. Cable length 1.5 metres. Measuring range: 1µS/cm to 2µS/cm.

Special conductivity cell probe TetraCon® 325/C:
As TetraCon® 325, 4-pole cell with integral temperature sensor, but with sensor head made of chemically resistant PEEK. Cable length 1.5 metres. Measuring range: 1µS/cm to 2µS/cm

Ultra-pure water conductivity cell probe LR 325/01:
With integral temperature sensor and flowthrough vessel D 01/T for measuring very low conductivity ranges (<1 µS/cm) e.g. boiler feed water or deionised water. Cable length 1.5 metres. Min. / max. insertion depth 35 / 110mm and flowthrough, measuring range: 0.001µS/cm to 200µS/cm.

Conductivity flowthrough cell TetraCon® DU/T:
4-pole conductivity cell with integral temperature sensor for standard applications. Connection via 10mm diameter tubing nozzles (the adapter cable KKDU with 1 metre cable is required for connection). Filling volume 7ml. Measuring range: 1µS/cm to 1000µS/cm.

IDS conductivity cell probe TetraCon® 925:
Intelligent digital 4-pole cell with integral temperature sensor. Automatical transfer of the cell constant. For connection to WTW IDS measuring instruments. Cable length 1.5 metres. Measuring range: 1µS/cm to 2µS/cm.

IDS conductivity cell probe TetraCon® 925/LV:
Intelligent digital 4-pole cell with integral temperature sensor. Fork design, suitable for small volumes (at least 2.5ml) as well as for viscous samples. Automatical transfer of the cell constant. For connection to WTW IDS measuring instruments. Cable length 1.5 metres. Measuring range: 1µS/cm to 2µS/cm.

IDS conductivity cell probe LR 925/01:
Intelligent digital 4-pole cell with integral temperature sensor and flowthrough cell D 01/T for measuring of low conductivity values (<1µS/cm) e.g. in boiler feed water or ion exchange water. Automatical transfer of the cell constant. Cable length 1.5 metres. Min./max. immersion depth 35/110mm and flow through measurement. Measuring range: 0.01µS/cm to 200µS/cm.

Product Specification:
Product Type: KKDU 325
Electrode: Connection cable
Shaft: -
Length: 100 mm
Cell constant: -

Catalogue Number9.704 079
ManufacturerXylem - WTW
Manufacturer P/n301963
Length mm100
TypeKKDU 325
PK1