pH-meter for measurement with analog conductivity sensors or digital Memosens-sensors
Multi meters Portavo 907 Multi
The only portable device for all Memosens parameters. Also for conventional analog sensors. The powerful Li-ion battery can be charged in the device via USB. The clear network diagram provides an at-a-glance view of the sensor condition.
The following logging types can be selected:
-Manual logging
-Time-controlled logging at a fixed interval
-Signal-controlled logging of measured value and temperature
-Combined time and signal-controlled logging
-Threshold-controlled logging with pre-trigger

The data logger for up to 10,000 entries records point of measurement, annotation, sensor ID, sensor serial number (Memosens), primary value, temperature, time stamp, and device status.

User-friendly software
Portavo 907 proves that a high level of functionality and easy use are not mutually exclusive. It proceeds step by step through the calibration procedure. Technical terms are clearly explained in the context-sensitive help.

-High-resolution color graphic display
-Transflective and sunlight readable
-Li-ion battery
-Micro USB port and Paraly SW 112 software
-A sensor quiver protects the sensor from damage and drying out
-The high-performance polymer housing ensures low water absorption and high impact resistance
-Intelligent data logger with 10,000 entries and graphical representation
-Memosens sensors and analog pH sensors can be used on one device (e.g. flat-membrane sensors)
-The mineral glass display is perfectly readable even after years
Specifications
pH/mV input (analogue):
pH: -2 to 16 (<0.01)
mV: -1300 to 1300 (<1% meas. val.,<0.3mV/K)
Temperature input:
Temperature with NTC 30 k© -20 to +120°C (<0.2K)
Temperature with Pt 1000: -40 to +250°C (<0.2K)
Memosens input (ISFET):
pH: -2.000 to +16.000 (<0.01)
mV: -2000 to +2000 (<1% meas. val.,<0.3mV/K)
Temperature: -50 to +250°C (<0.2K)
Memosens input, Redox:
mV: -2000 to +2000 (<1% meas. val.,<0.3mV/K)
Temperature range: -50 to +250 °C (<0.2K)
Conductivity measuring range: 0.001µS/cm (c<0.05cm-1)
0.01µS/cm (c=0.05 to 0.2cm-1)
0.1µS/cm (c>0.2cm-1)
TDS: 0 to 1999mg/l
Salinity: 0.0 to 45.0g/kg
Resistivity: 00.00 to 99.99M© x cm
Concentration: 0.00 to 9.99 (w/w) %
Conductivity input (analogue):
Measuring range with
Sensor SE 202: 0.01 to 200 1/4S/cm
Sensor SE 204: 1 1/4S/cm to 500mS/cm
2-electrode sensors: 0.1 1/4 S x c to 200mS x c
4-electrode sensors: 0.1 1/4 S x c to 1000mS x c
Temperature input:
Measuring rangewith NTC 30 k©: -20 to +120°C
Measuring range with Pt 1000: -40 to +250°C
Conductivity input, Memosens:
Measuring range Sensor SE 215 MS: 10 1/4S/cm to 20mS/cm
Conductivity input:
Temperature compensation: linear 0 to 20%/K, ref. temp. adjustable
nLF: 0 to 120 °C
Memosens input, oxygen (optical):
Saturation: 0.000 to 1000.0%
Concentration: 000 1/4g/l to 100.00mg/l
Partial pressure: 0.0 to 2000mbar
Temperature measuring range: -20 to+150°C
Power supply: 4 x AA
Protection class acc. to DIN EN 60529: IP66/67 with pressure compensation

Product Specification:
Product Type: 907 Multi Cond
Description: one additional input for analogue conductivity mesurements

Catalogue Number9.774 717
ManufacturerKnick
Manufacturer P/n907 MULTI COND
Type907 Multi Cond
Descriptionone additional input for analogue conductivity mesurements
PK1
Your basket is empty
Powered by Prospect

We use cookies to give you the best possible experience on our site. By continuing to use the site you agree to our use of cookies. Dismiss | More Information X